closer air valve

RELATED FAQS

Question
Answer
The hydraulic closer underneath the control box has 3 regulating valves (like any 4040 series hydraulic closer). Main Speed - adjust closing speed from 90° open down to 10°. Latch Speed - adju...
The part number for the solenoid air valve in the 7900 Series control boxes are: 7901/ES7901 - part# 941 - marked A 7902(S)/ES7902(S) - part# 942 - (2 valves) marked A and B 7949/ES7949 - part...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
The valve on the back of a 4041/4040XP closer is a "Back Check Selector Valve" that needs to be turned in on "Parallel Arm" mount applications ONLY. If a 4041/4040XP closer mounted "Top Jamb", or "...
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees. ...
The 4110 closer is handed, and will have an "RH" and "LH" on the casting next to the closer shaft. The regulating valves are going to be on the same side as the hand of the closer.
4040XP Series (4040 DEL) is a universal closer. *(see note) Non Handed closer. Can be mounted on a RH or LH door. 4041XP - Adjustable size 1 to 6. Can mount push side or pull side of the doo...