What is the power draw of a Senior Swing series operator?
Resolution:
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/...:
What is the input / output of the 8200 series operator?
Resolution:
The Falcon 8200 series operator requires a input of 120 VAC @ 1 Amp.:
Why is the battery draining so quickly on an AD-Series lock with a Keypad ONLY (KP) credential reader?
Resolution:
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.:
What current should an AD-Series or CO-Series lockset draw while in its low power "Sleep" mode?
Resolution:
Use a multi-meter in series with the batteries to measure battery current. Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...:
What gauge wire is needed for CX red and black power wires?
Resolution:
For Product Shipped prior to 8-24-2015 with solenoid and EPT or Door Loops: a. 0-100 ft, use #14 Gauge Wire ...:
Why is my Von Duprin Chexit device not lighting up or arming?
Resolution:
Devices were shipped from the factory with solenoid driven prior to 8-24-2015. First confirm that you are using a PS873 or PS914 power supply.Measure the DC voltage at the ten wire hardness a...:
Why does a Chexit device blink once then powers down?
Resolution:
If Chexit device LED blink once when you turn the unit on, the External inhibit green wire is not by passed or not connected to the access control normally closed contact. For devices sh...:
What is the amp draw of the LCN ME and SE closers?
Resolution:
24 volt version draws 90 mAmps (0.090A). 120 volt version draws 30 mAmps (0.030A). See here for the LCN catalog sheets that contain this information (page 2 of 48). :
What is the draw amperage for the E996L?
Resolution:
PS902 is a 2 amp power supply and each E996L electric trim draws 0.25 amps at 24VDC. You can have up to eight E996L electric trim per PS902 power supply.:
Why does the fuse blow in the power supply when arming the Von Duprin Chexit device?
Resolution:
The following could cause the fuse to blow in the power supply with devices shipped prior to 8-24-2015 with solenoid driven when Chexit device is arming. Wrong power supply Confirm PS873 or...:
How many Chexit devices can be operated from the PS914 power supply?
Resolution:
Following information determine number of the Chexit devices that were shipped prior to 8-24-2015 from the factory with solenoid driven can be hooked up to a single Von Duprin PS873 or PS914 p...:
What are the amperage and power supply requirements for the Von Duprin Chexit (CX) devices?
Resolution:
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gau...:
How much amperage does the QEL draw?
Resolution:
Applies only to Von Duprin QEL exit devices shipped after December 11th, 2014.1.0 amp inrush and a 0.14 amp holding current.: