Card reader auto operator senior swing
”
RELATED FAQS
Question
Answer
What are ElectroMechanical Automatic Operators?
Resolution:
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...:
What is the power output of a 4600 operator?
Resolution:
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...:
What is the difference between the Senior Swing 9540 and 9530 Series power operators?
Resolution:
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...:
How do you install a Senior Swing 9540 on one leaf of a double door?
Resolution:
Surface Mounting - A 9542 HDR2 (Double Door Header) and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can then be installed on the inactive leaf....:
How do I get service on my Astro Swing operator that isn't working properly?
Resolution:
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
How is a ELR or panic device wired to a Senior Swing?
Resolution:
EL devices are wired to the Senior Swing, using the P10 (761465) cable. Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...:
Does the 9540 Senior Swing need a separate relay board for wiring to electric locks?
Resolution:
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.: