can we use Less bottom rod exit devices in single doors?
”
RELATED FAQS
Question
Answer
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
What causes the top rod case to pull away from or strip out of the face of a steel door?
Resolution:
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...:
Can the 9927 exit device be installed Less Top Rod?
Resolution:
The top rod is required for proper operation. The top latch controls both the top & bottom rods and without the top latch/rod the bottom latch would release when pushpad or trim was used but then ...:
Can you do LBR on a 98/9947 WDC?
Resolution:
This is available. If this is a fire rated opening you must use the Auxiliary Fire Latch Kit to maintain your Fire Rating. If not fire rated simply omit the bottom rod but be aware that your...:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
Can I use an AD or CO - 993 Exit Trim with a Von Duprin 98/99 Concealed Vertical Rod exit device on a wood door?
Resolution:
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.: