can frames with sanitary stops be sound rated

RELATED FAQS

Question
Answer
Yes, hospital stops are available on fire rated frames. Maximum approval = 3 hour Maximum sizes:  singles up to 4'0" x 8'0" pairs up to 8'0" x 8'0" Maximum hospital stop height 6" from bot...
Hospital Stops are located at the bottom of the frame jambs and/or mullions. The integral door stops are terminates above floor line and is closed with a 45° or 90° angle to facilitate cleaning at ...
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
Make sure the lock AA batteries are good. 4.8 VDC or higher.
When in its “Active state”, the mechanical key switch can prevent USB connection. Make sure the lock key cylinder and tailpiece are properly installed.
Make sure the mechanical triangles on the back of the outside escutcheon are aligned properly.  See the installation instructions at www.schlage.com/support Schlage Technical Support.&nbs...
If the Schlage Utility Software pops up a "E201 error", just ignore it, and tap "Device Options" or update your firmware. See 78451  
Make sure the HHD/SUS is set to USB communication by checking the small icon right of the "No Device Connected" message.  The symbol should be a USB symbol when working with USB enable product...
For Motor driven Chexit devices shipped from the factory after 8-24-2015, the Chexit Secure Relay Contacts( white and violet wires) change state to signal the device is not secure. Check the f...
For Solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the following could cause the device not to provide delay egress:Measure the voltage between green and orange wires o...