 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed.  In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.
ALL AD and CO products are warranted for electrical for 1.0 year after installation OR 2.0 years after manufacture. The mfg date is on the lock stickers AND can be viewed electronically with th...
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...