Question
Answer
Why is the Von Duprin PS873 power supply buzzing or chattering?
Resolution:
Some transformers in the power supplies provide a little humming noise and that is normal. If the humming in Von Duprin PS873 power supply is loud follow these steps. Remove the load from the outp...:
How many Von Duprin ALK's can be powered off a PS900 series power supply?
Resolution:
The Von Duprin exit alarm ALK draws about .25 amp. PS902 power supply powers up to 8 exit alarm ALK. PS904/914 powers up to 16 exit alarm ALK. PS906 powers up to 24 exit alarm ALK. :
Is there a wiring diagram for EL and Von Duprin PS914-2RS power supply?
Resolution:
Reference The 914 Installation instructions.:
Will one PS902 power supply run two Von Duprin exit alarm ALK'S?
Resolution:
PS902:
Will the Von Duprin PS902 power supply operate the QEL device?
Resolution:
The Von Duprin PS902 power supply will operate the QEL device as long as you also use the 900-2Q board for devices shipped prior to September of 2012. After July of 2012, the 900-2RS boa...:
What power supply replaced the Von Duprin PS861?
Resolution:
The PS902 power supply replaced the Von Duprin PS861 power supply.:
What power supply replaces the Von Duprin MPB840 or MPB842?
Resolution:
MPB840 = PS914power supply, MPB842 = PS914-2RS power supply.:
Should terminals SC and I1 have constant 24VDC on Von Duprin PS873-2 power supply?
Resolution:
Yes, SC and I1 measure 24VDC.:
What is the power output of a 4600 operator?
Resolution:
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...:
After replacing the battery on a Von Duprin 2670 Guard X why would the horn stop working?
Resolution:
Replacing the battery on the 2670 should not cause the unit stop working. Make sure the spring that provides tension on the plastic finger is not bent out. The spring should be at a 90 degrees...:
Why does the fuse blow in the power supply when arming the Von Duprin Chexit device?
Resolution:
The following could cause the fuse to blow in the power supply with devices shipped prior to 8-24-2015 with solenoid driven when Chexit device is arming. Wrong power supply Confirm PS873 or...:
What is needed to keep the EL device retracted all day?
Resolution:
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...:
How many Chexit devices can be operated from the PS914 power supply?
Resolution:
Following information determine number of the Chexit devices that were shipped prior to 8-24-2015 from the factory with solenoid driven can be hooked up to a single Von Duprin PS873 or PS914 p...:
What power supply is need for Falcon EL devices?
Resolution:
The Von Duprin PS914 power supply with either the 900-2RS or the 900-4RL option board is required.:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
What are the amperage and power supply requirements for the Von Duprin Chexit (CX) devices?
Resolution:
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gau...:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...: