Question
Answer
Can the 4630/4640 cylinder only be replaced?
Resolution:
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...:
Can an auto operator be installed on a Dutch door?
Resolution:
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...:
What power supply do I need for my 2 QELA devices with LCN auto operator?
Resolution:
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...:
What wires are the activation inputs for the Senior Swing?
Resolution:
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. ...:
Can a Senior Swing 2850 or 2860 be used on a Double Egress (DE) door?
Resolution:
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
Which terminals on the 4630/4640 operator are used for activation?
Resolution:
The 4630/4640 operator activation inputs are: Normal Activation Inputs (2 parallel) - terminals 16 & 17 or 18 & 19. Sequential Input - terminals 8 & 19. Alternate Action Input - terminals 15 &...:
What are ElectroMechanical Automatic Operators?
Resolution:
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What power operator is recommended/used for occasional activation with mainly manual traffic?
Resolution:
The 4630/4640 Series operator is designed/recommended for a door that will see mostly manual traffic with the occasion automatic/ handicap operation.: