Why would a Falcon 8200 operator have an inconsistent opening?
Resolution:
An inconsistent opening is normally caused by the arm not being installed correctly. The arm must be installed while the operator gearbox is in the full open position, and the door at 90° open posi...:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
What is the difference between a 4630 and 4640?
Resolution:
4630 Single Arm/Track style. Mounted on the Pull Side of the door. Non Handed 4640 Double Arm style. Mounted on the Push Side of the door. Non Handed:
Can the 4630/4640 cylinder only be replaced?
Resolution:
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...:
What is a Senior Swing 9540 RF?
Resolution:
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...:
What is the power output on the Senior Swing 9500 series?
Resolution:
Below information is for the 120v Sr Swing Operators.For Sr Swing digital Control Boxes made from 2006 to Dec. 9th 2019 the Senior Swing operator had a 24VAC output , rated at 1.5 Am...:
Can a Senior Swing 2850 or 2860 be used on a Double Egress (DE) door?
Resolution:
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...:
What wires are the activation inputs for the Senior Swing?
Resolution:
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. ...:
What is the maximum reveal for a regular arm 4642 operator?
Resolution:
Max. reveal for a 4642: 4640 Regular arm -- 4.5" 4640 Long arm -- 8" 4640 x ST-3088 ( custom made - extra long rod) -- 8" to 11" No special mounting instructions required, just standard templ...:
Which arm is the same as the 4640 regular arm?
Resolution:
The 4640 Regular arm (4640-3077) is the same as: 4040 Long Arm 4820 Regular arm. The arms listed above are for reveals up to 4 1/2" and have a 8 3/8" long rod and shoe. 4640 Long arm ...:
What is the minimum and maximum reveal for a 9500 Series Senior Swing operator?
Resolution:
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
How do you install the arms on a 9100 Series Benchmark operator?
Resolution:
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...:
How do I program my device?
Resolution:
The programming processes for Allegion devices can be both product and features specific. Some products programming processes are electronic in nature, others are physical in nature. &nb...:
How do I get service on my Astro Swing operator that isn't working properly?
Resolution:
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...:
What power supply is required for two EL devices and one LCN auto operator?
Resolution:
Von Duprin PS914 x 900-4RL supports two EL with two auto operator.:
What is the difference between the Senior Swing 9540 and 9530 Series power operators?
Resolution:
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...:
How do you change a 9130 Benchmark to a 9140 Benchmark?
Resolution:
The only difference between the 9130 and 9140 Benchmark operators are the arms.To convert a Benchmark 9130 (pull) to a 9140 (push), order a 9140-3077 push arm assembly for revea...:
What would cause a Senior Swing to open too far?
Resolution:
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...: