ad series access control software not reporting

RELATED FAQS

Question
Answer
Partner Solution: Integrated Access Control Solution with AD-300 Hardwired, AD-400 Wireless Locks and Avigilon RedCloud Access Control System.See the download cut sheet at:Avigilon Red Cloud&n...
A computer based program controlling access privileges and monitoring the status of openings.
Can I get Excel spreadsheet data from my Schlage Express Software reports? Yes... in any already generated report from Schlage Express, right click anywhere in the "white space" and Select Expo...
When the new PS900 series power supplies were created we did not pursue a version of these option boards.  Need to discuss the specific hardware they are using and requirements to determine the app...
When the SUS and HHD are used in the “Auto Update” mode, the audit info will be automatically gathered each time the SUS is successfully connected with a lock.
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
The FMK reader on an AD Series lock is capable of reading PIV and PIV-I credentials, however, alone it no longer complies with the new FIPS 201-2 standard in which the lock with reader (AD-302 and ...
Coin cell replacement is not immediately registered by the AD200/250 firmware.
Performing a processor reset (pressing and releasing S1 on the Main PCB Assembly) will register the new coin cell.
Cycling lock power (i.e., disconnecting and reconnecting the "AA" battery pack) will register the new coin cell.
The coin cell part number is CR2025 - 3 volt lithium - available at most battery or electronics stores.
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is i...
“Cache Mode” is an AD-Series feature which, accumulates and stores valid credentials that have recently been granted access by the Access Panel or head-in system. This recently granted access histo...
The number of bits selected for "Card Bit Format" on an AD400 or AD300 must be equal too or larger than the bits on the cards in use. Setting this number correctly enables the cache mode collectio...
The AD300 and AD400 devices do not store audits during cache mode.  Audit "Date and Time" information and the saving of audit information is an Access Control Panel function, and during cache mode ...
An AD400 granting credentials access in “cache mode” will blink the Schlage with the normal green LED, followed by a brief red Schlage LED flash, indicating no RF communication and access was grant...
Update the PIB300-2D firmware to version 2.13.1 or higher to be compatible with Brivo Access Panels
Update the PIM-400-TD2 firmware to version 2.14.2 or higher to be compatible with Brivo Access Panels
If an access control system is not available to test the card output on a hand reader, this card emulation test can be done to verify the card format is correct.  These steps will guide you in...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
Following items could cause the DC output on PS914 series power supply to drop when access control is activated. Wrong gauge wire from power supply to the the power transfer. Excessive wire run...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...