actuator for paired opening
”
RELATED FAQS
Question
Answer
What would cause a 4600 Series operator to open up and intermittently stick open?
Resolution:
If manually it opens and closes fine, check to make sure one of the actuators is not getting stuck in the on position. Verify that the "Operating Indicator" LED's -- "POWER and SAFETY CLEAR" LED's ...:
What is an error code E04 on an LCN 4600?
Resolution:
An error - E 04 - is an indication of a constant activation input from either the "Hold Open" switch or a "Wall Activation" switch when the 4600 power is turned on. This condition also occurs when ...:
Can a 8310-818 be used outside?
Resolution:
Exterior mounting of the 8310-818 series actuators is not recommended. The 8310-818 series actuators are designed to be jamb mounted on the frame. With that installation, the person will have to ...:
What components are needed to convert a hard wired actuator button to a wireless actuator button?
Resolution:
To convert an RF actuator button to a hard wired actuator button, simply remove the RF transmitter an connect the hard wiring to the "Common" and "Normally Open" terminals on the the switch.:
Can a wireless actuator be converted to hardwired?
Resolution:
Yes. Remove the receiver from the operator. Remove the transmitter from the actuator button. Attach 1 wire to the NO (normally open) contact on the actuator switch, and another wire to the COM (com...:
Why would a Falcon 8200 operator have an inconsistent opening?
Resolution:
An inconsistent opening is normally caused by the arm not being installed correctly. The arm must be installed while the operator gearbox is in the full open position, and the door at 90° open posi...:
How do you install the arms on a 9100 Series Benchmark operator?
Resolution:
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...:
How do you program the 8310-865 RF receiver?
Resolution:
To program the 8310-865 receiver: Set the dip switches 1 to the "OFF" (pulse) position. Set the dip switches 2 to the "OFF" (0.5s) position. Momentarily press the " No Delay" or "Delay" ...:
What is the 7910-956 direct crossover?
Resolution:
The 7910-956 actuator direct replacement is the 8310-856 actuator.:
What are the ANSI recommendations for the actuator mounting height and distance between the wall actuator and the door opening?
Resolution:
Always check the most current revision of the ANSI A156.19 standard for recommendation or requirement of the location of a Knowing Act switch. 2019 ANSI A156.19 states the requirement of the ...:
What would cause a 4600 operator to click a few times when the actuator is pushed, but not open the door?
Resolution:
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...:
What could cause a 9100 Series Benchmark operator not to open when the actuator is pushed?
Resolution:
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...:
Which strike do you use with an XP98/99 device?
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Can we have 9927-F LBR and 9975-F on a paired opening?
Resolution:
This combination is not available. The 98/9927-LBR-F has only been UL tested as vertical by vertical combination on pairs of fire rated doors.:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...:
What power supply do I need for my 2 QELA devices with LCN auto operator?
Resolution:
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...: