Answer
What application does the L9094 serve?
Resolution:
The L9094 was designed for retrofitting into an existing door prep that also has an inside cylinder. :
What wire gauge is the Allegion Connect harnesses?
Resolution:
The Allegion Connect wire harnesses use 20 AWG (American Wire Gauge). The molex connector and pins provided with the Allegion Connector Kit (CON-KIT) can accept wires between 20 AWG (maximum) ...:
Is the AX option available for Falcon 25 series devices?
Resolution:
The Falcon AX option is available on a limited number of Falcon exit devices and has a $19 list add. To receive an AX device that requires only 5 pounds of force to operate please specify the AX ...:
Are any Mounting options included with SERIII-W-GR Scramble Keypads?
Resolution:
No, there are (4) Mounting kits availble but must be ordered sepeartely. &nb...:
Can the current versions of GF3000 Shear Locks be mounted vertically?
Resolution:
No, the current version of the GF3000 has the coil fixed without springs and cannot be mounted vertically. Older versions had springs which would allow vertical installs. :
Is the wired remote release only on the AD-200 lockset?
Resolution:
Yes, the new AD-Series wired remote release is only available on the AD-200 lockset .:
Can any AD200 lock be made to work with the remote release feature?
Resolution:
No, only an AD200 with a Main PCBA with hardware revision âFâ or higher must be used.:
I have an AD200 with the latest revised hardware "rev F" and I can't get my remote release function to work.
Resolution:
The AD200 with main pcba rev F or later are required to support the remote release feature. But you must also have the AD200 programmed with firmware package AD.A.80 (or higher). You mu...:
Where do I connect the wires for the AD200 remote release feature?
Resolution:
The remote release wires need to be connected to the AD200 Latch Bolt connector. You must also have an AD200 with main board revision F or later and select the Storeroom function on the Edit Tab in...:
I have a new AD200 with the latest firmware and after I connect my wires to the remote release button I still cannot get it to function properly.
Resolution:
You will need the following: AD200 Series lock with main board rev F or later Firmware that is AD.A.80 or later Select "Storeroom" function in SUS on Edit Tab Connect wired remote wires to latch bo...:
«