Question
Answer
Is the Ives #4 catch still available?
Resolution:
The Ives #4 catch was discontinued in 2009.:
PS873 with a new main board and no voltage on outputs.
Resolution:
Issue: Power supply with no outputFacts: PS873Resolution: Check the fuse and if bad replace with 4 amp slow blow fuse. If Fire Alarm (FA) board is used confirm that the Fire Alarm is closed a...:
HHD is not recognized after installing Windows mobile device center on Windows Vista or Win 7
Resolution:
Ensure that the HHD is not connected to the PC during WMDC installation.Install "Microsoft Windows Mobile Device Center 6.1 or higher for Windows Vista / Win 7( ensure correct bit 32 or 64 is being...:
Schlage Express: Why does generate program files continue to blink after HHD is returned to PC?
Resolution:
This is a known error but does not have any effect on programming doors.It can sometimes be corrected by reprogramming the same set of doors and with Express running allow the hhd and pc the sync a...:
What mag lock replaced the 390+?
Resolution:
The nearest functional replacement is the M490 although the foot print differs.The 390RFK is a similar unit that will fit the the same prep ads the legacy 390+ :
Using NetSuite to Verify XceedID Order Information
Resolution:
**ALLEGION INTERNAL USE ONLY** To verify a facility/site code on an order or any other information, use the attached guide to NetSuite.Netsuite Login Tutoria
[email protected]
Tech...:
How to reset Late production CM and Pro locks that have a clr button.
Resolution:
Remove inside cover On the circuit board, press the CLR button 3 timesreplace cover:
Reset AD400 lock to factory defauit
Resolution:
Hold the Schlage Button until two green flashes of LED or two beepsPress IPB (large button on circuit board) three timesYou will then hear one long beep to confirm it has been defaulted.:
How do I reset the AD200 lock back to factory
Resolution:
Level 1 Factory Default Reset- Level 1 factory default reset will delete configurations and settings in the main controller in the lock. - Main controller configurations that will reset...:
Reset CO100 lock to factory default
Resolution:
Remove 1 battery Wait several seconds or press schlage button several times to help drain batts. Press and hold Schlage button while replacing battery. Hold until two beeps an...:
«