Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
317
318
319
320
321
»
Question
Answer
What is the right way to use multiple PIM400 on the same Bright Blue channel?
Resolution:
Set PIM400 Address The SUS is used to set the address of the PIM400. The address of the PIM should be set to the lowest number available, from 0 to 15. A maximum of sixteen (16) AD-400 Locks...:
What is the part number for a full size construction control key?
Resolution:
The Schlage full size construction control key part number is 48-056-ICX. The ICX suffix will change depending on if the key is for a new job or existing job. New jobs: Specify "ICX" E...:
What deadbolt series does the CS210 use?
Resolution:
The CS200 uses a B500 style deadbolt. :
Can an 18-R-L be converted to L-NL function in the field?
Resolution:
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).:
Is there a parts diagram for a 996L trim?
Resolution:
Reference the 994L trim which has the same internal parts in the parts manual.990 Parts Manual:
Explain the function for the L9485.
Resolution:
L9485: Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn. When deadbolt is thrown, all keys become ino...:
Are the 6000 series strikes field selectable for 12 or 24 VDC?
Resolution:
All 6000 series electric strike would require the solenoid be replaced to convert from one voltage to the other.:
Can you change the handing of the 2090 in the field?
Resolution:
The 2090 is handed and is not reversible.:
What is a setup key?
Resolution:
A setup key is an Everest key that has had the upper half of the blade removed. A setup key is an Everest key that has had the upper half of the key blade removed. See picture. A ...:
How thick of a door can a 99L x 996L be installed?
Resolution:
1 3/4" - 2 1/4" is standard > 2 1/4" up to 4" is an Engineering special.:
«