Is there a set screw on the solenoid plunger of a Chexit device like there is on an EL solenoid?
Resolution:
Devices shipped after 8-24-2015 are motor driving and no longer have solenoid. Devices shipped prior to 8-24-2015 with solenoid driven: There is no set screw on the solenoid of the Chex...:
Why won't the 5100 24v strike work on both a RH & LH door?
Resolution:
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...:
Will the PS914 or PS873 replace the RDS-2?
Resolution:
This is not an option, the older RDS-2 was used with the older Falcon Monarch ELR devices. The power supply would apply 24VDC for 1 second then drop down to 5VDC for the remainder of h...:
Does the cam have to be inverted for cylinder dogging on the falcon 25?
Resolution:
The cam is not inverted on the mortise cylinder for the CD option.:
What is the part number for the Fail Safe slider for the 6211?
Resolution:
The sliders are different between the 6211 and 6211WF. The FS slider part number for the 6211 is 090591 The 6211WF FS slider is 090798. :
Can SRT screws be used in a wood door or frame?
Resolution:
LCN "does not" recommend the use of SRT screws is wood doors. LCN "only" recommends the use of Wood Screws in wood doors and frames, as noted on the installation instructions.:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
How do you turn a Handkey to Time/attendance mode
Resolution:
T&A feature can be enabled the on a HK2 via password menu 2 and after SET ID LENGTH. Hit yes for T&A MODE.:
What wiring is needed for the HandPunch?
Resolution:
The HandPunch can be hard wired for communications using RS-485, RS-422, or RS-232. Using RS-485 or RS-422 requires a data converter. The data converter part numbers are DC-102 (4-wire)...:
What is a KD frame?
Resolution:
Knock Down (KD) frames: KD frames are designed, manufactured and supplied with integral miters which include all notches, interlocking corner tabs and slots to allow for field assembly and do not r...:
«