Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
FAQs
«
230
231
232
233
234
»
Question
Answer
How is the 4582 strike handed?
Resolution:
The 4582 is handed because the latch pocket is not centered on strike plate. the 4582 can't be handed in the field. See attached information: 4582 Handing:
What is a Von Duprin 893P strike?
Resolution:
The 893P is not a strike, it is the UL label on a 6000 series strike. This label will not describe the strike you have.:
Would the 900-4R option board control EL devices in a PS914?
Resolution:
The 900-4R is used with PS900 series power supplies and has four independent outputs and inputs with no time delay. You can use any of these outputs with electrified hardware including EL devices a...:
When would you use the 900-4R option board in a 900 series power supply?
Resolution:
The 900-4R is used with PS900 series power supplies. The 900-4R has four independent outputs and inputs with no time delay. You can use any of these outputs with electrified hardware including EL...:
How do you convert an AL44 to an AL40?
Resolution:
To convert the AL44 to an AL40 you can replace the outside plunger unit in the chassis or order the AL40 chassis. Replacing the plunger unit is more difficult and time consuming and would not be r...:
What is the difference between Night Latch (NL) and Class Room function?
Resolution:
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...:
Is the FB51P strike same as FB31P strike?
Resolution:
The top strikes are different. The FB31T is a flat strike where the FB51T is a lipped strike. Both units use the same bottom flush bolt and strike.:
Will the 996L trim cover a 161 prep?
Resolution:
The 996L trim will cover the 161 prep.:
How do I know if the AC current is being applied to the PS 914?
Resolution:
Measure the AC voltage on AC terminal blocks with a voltmeter, it should measure 110-240VAC. Also check the AC green LED indicator to see if it is on. If the LED is not on, you may have a blow...:
Is there a "programming card" that is used with either the SXF1050 or 1550 to change the card output to a continuous 26 bit output?
Resolution:
Standard Prox-only card readers cannot be programmed. Multi-Tech readers can be. The configuration cards also do not determine the bit output. The readers are pass through devices so wh...:
«
230
231
232
233