Question
Answer
How is the ND170 installed?
Resolution:
To install a Schlage ND170 click here for the installation instructions.:
What grade is the B250 and is this product UL listed?
Resolution:
The B250 is Grade 2 but has no UL listing due to the holdback rose.:
Can the 386DT be used with 330 dummy bar?
Resolution:
Use the 050144 mounting package for 1 3/4" door thickness.:
Is the HL6 ADA compliant?
Resolution:
The HL6, PL7, PL8 meet ADA guidelines.ADA compliant letter:
Does the Von Duprin Chexit work with the "Wander Guard" system?
Resolution:
The Von Duprin Chexit device can be used in conjunction with Wander Guard or Baby Detection systems if wired in correctly. Set the rearm time on Chexit module to zero second. It will be...:
Can you change from standard mounting packs to type O mounting packs on the Ives 8190 pulls?
Resolution:
Yes, both mounting types the handle is mached the same with a 1/4-20 threaded hole:
Is a rectifier needed to change AC to DC on Von Duprin 6000 series electric strikes?
Resolution:
The strike will always be DC. By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.:
Instructions for the discontinued 5527.
Resolution:
The 5527 is no longer available, Contact support for further assistance . 877-671-7011, option 2, then option 3.:
What is the LM9000 mortise lock?
Resolution:
The Schlage LM9000 Multipoint Solution was a three-point locking assembly that was UL approved to FEMA 361 and FEMA 320 guidelines for outswing doors, and met ANSI ICC 500 for tornad...:
What is the part number for a 98/99 or 33A/35A exit device baseplate assembly?
Resolution:
The baseplate assemblies are not saleable parts.:
«