Question
Answer
TX (Tsunami) Enclosure installation
Resolution:
TX (Tsunami) Enclosure installation:
HandPunch or Handkey II F-Series G-Series Allergen Statement
Resolution:
F-Series G-Series Allergen Statement:
What Windows' operating systems are compatible with HandNet for Windows?
Resolution:
Handnet for Windows Operating Systems CompatibilityHand Net for Windows has been tested with the following operating systems:· Windows XP Professional Service Pack 2 (US English edition)· Windows X...:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...:
Can I use a 4040 EDA and a Glynn Johnson 100 series concealed stop together?
Resolution:
There is not a conflict between the 4041/4040XP EDA door closer and the GJ 100 or 410 overhead concealed series stops. The exception is: the 4041/4040XP mounted on a drop plate, and the Glynn Jo...:
Can 576A or 576B strikes be used on wood doors?
Resolution:
The 576A or 576B strikes can be used on wood doors but you should check with door manufacturer if it is a fire-rated door to make sure there are no conflicts.:
How do you order a 4110 hold open spring cush arm only?
Resolution:
The 4110 hold open spring Cush (Spring H Cush) arm part number is 4110-3049SCNS.:
What is the difference between a 1460 and a 1461 closer?
Resolution:
As of today the 1460 is the closer "series number", and 1461 is the closer "model or ordering # ". Both numbers represent the same door closer, there is no difference.:
What is the holding force of a SEM magnet?
Resolution:
The SEM series magnets have a holding force of approximately 35 lbs when installed according to LCN instructions.:
What are the thermal factors for Steelcraft door products?
Resolution:
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners) U-Factor = 0.50 R-Value = 2.01B16 Series (Steel Sti...:
«