Question
Answer
What LCN closer is used for double acting door?
Resolution:
The LCN 6030 is a Double Acting (or dual action) closer. Requires a "Cased Open Frame" - that means no stops formed in the frame.:
What special template (ST) is used with a 4040XP Cush, a 7/8" 5TH screw spacer, and 1/4" solid weather strip?
Resolution:
ST-1595 is used to template a 4040XP CNS/HCNS/SCNS/SHCNS closer, with 1/4" solid weather strip and a 7/8" 5th screw spacer.For current ST add on pricing and templ...:
Are doors available for use with non Steelcraft window kits?
Resolution:
Doors are available with cutouts only. This practice is used for field installation of aftermarket (non-Steelcraft) glass trim by either the distributor or end user. The following information must ...:
What are the standard hinge and lock spacing for doors and frames?
Resolution:
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening&n...:
What is the default password to log into HandNet for Windows?
Resolution:
Log in is "1234" and the password is "new".:
What is the default password to log into HandNet Lite?
Resolution:
Log in is "1234" and the password is "new".:
What are the standard door and frame clearances?
Resolution:
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...:
How to revert to Network mode via Telnet on the GT-400 reader
Resolution:
1. Stop the Terminal application 2. Delete the Terminal database 3. Start the Terminal ...:
Is the ND lock available to accept Sargent, Corbin Russwin, Yale or Medeco cores or cylinders?
Resolution:
Only the Schlage ND-Series can be prepped to accept non-Schlage cores. All designs are supplied with the appropriate tailpiece Non-Schlage cores are NOT included Lever designs ...:
Can a 4040XPT DE be used with a 4" reveal on the pull side?
Resolution:
The LCN 4040XPT with a reveal deeper than 1/8" on the pull side of the opening requires a Double Egress (DE) arm.DE arms are handed arms and cannot have handing changed in field.ST3073 Standard 404...:
«