Does the Chexit device retract the latch bolt?
Resolution:
The Von Duprin Chexit device does not have electric latch retraction feature.:
How far down can you cut a 4' 19R?
Resolution:
The 4' (F) 19-R with standard F570 strike can be field sized to fit down to a 3'0" Door Opening Width per chart on page 18 of 19 Series Catalog.:
Does the CO100 have a coin cell?
Resolution:
There is not a coin cell on the CO100.:
What is the UL Fire rating on the 4040SE closer?
Resolution:
The 4040SE series closer is UL10C listed for 3 hours.:
What is 365R?
Resolution:
365R is the UL file number for the 6000 series electric strikes fire rating. :
Solenoid on Chexit pulls back and immediately lets go and alarm goes off with red solid light.
Resolution:
The following could cause the Chexit solenoid ( devices shipped prior to 8-24-2015) pulls in then drop out with no alarm. Mechanical adjustment such as vertical rods. Disconnect t...:
What is the amp draw on EL device?
Resolution:
The amp draw on EL device is16 amp inrush with .3 amp holding.:
Can the Von Duprin Chexit device be changed to ALK exit alarm?
Resolution:
The Chexit device has a different base plate and center case than the ALK. The Chexit device would need to be replaced with an ALK device.:
Can I put an old style hex dogging kit (050153) on my 99 panic device?
Resolution:
We don't recommend to use the old style hex dogging kit into the new 98/99 exit device but it would fit as long as the device is not fire rated.:
Will Falcon B locks prepped for BD accept a 6 or 7 pin core?
Resolution:
The B series accepts 6 or 7 pin small format cores when specifying with the "BD" cylinder suffix (less small format interchangeable core). The tailpiece shown below is used for bo...:
«