Question
Answer
Why would the controller on my 4600 (4630/4640) have no lights on display when powered with 120 VAC?
Resolution:
Verify that the 120VAC is present at the controller (measure 120VAC on the 2 wire gray cable from I/O board to controller -- red/black wires in gray cable). If present, but no lights on the contr...:
Will a 4040 Hw/PA hold open at 180°?
Resolution:
The 4041 Rw/PA and the Hw/PA have the same template. The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...:
How is the 8310-877 wired to the 4600 (4630 4640) operator?
Resolution:
The 8310-877 comes with a 6 wire cable. You have to cut the connectors off both ends and hardwire it to the 4600 operator as follows: The 6 wire cable connections to the 7 pin connector in the 8310...:
Does the Chexit device retract the latch bolt?
Resolution:
The Von Duprin Chexit device does not have electric latch retraction feature.:
How far down can you cut a 4' 19R?
Resolution:
The 4' (F) 19-R with standard F570 strike can be field sized to fit down to a 3'0" Door Opening Width per chart on page 18 of 19 Series Catalog.:
Does the CO100 have a coin cell?
Resolution:
There is not a coin cell on the CO100.:
What is the UL Fire rating on the 4040SE closer?
Resolution:
The 4040SE series closer is UL10C listed for 3 hours.:
What is 365R?
Resolution:
365R is the UL file number for the 6000 series electric strikes fire rating. :
Solenoid on Chexit pulls back and immediately lets go and alarm goes off with red solid light.
Resolution:
The following could cause the Chexit solenoid ( devices shipped prior to 8-24-2015) pulls in then drop out with no alarm. Mechanical adjustment such as vertical rods. Disconnect t...:
What is the amp draw on EL device?
Resolution:
The amp draw on EL device is16 amp inrush with .3 amp holding.:
«