What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
What can be done for a door that will not close against wind pressure?
Resolution:
To correctly answer this question, we need to know how much more force is required to get the door closed. They could try turning the Rod & Shoe over (short side of shoe towards the hinge), or they...:
What would cause a Falcon 8200 (8230/8240) operator to slam the door closed?
Resolution:
The Benchmark 9100 series and Falcon 8200 Series operator will allow the door to slam if: The motor is not connected (plugged into) the controller as the closing speed is controlled by a c...:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
What does a blinking TROUBLE LED (D1/D2) mean on my PIM400-TD2?
Resolution:
a) One blink of the TROUBLE LED means the AD400 on this channel has low AA batteries. Install fresh batteries. b) Two blinks of the TROUBLE LED means the AD400 on this channel is not communicating...:
What does a blinking TROUBLE LED (D1/D2) mean on the PIB300?
Resolution:
3) Five blinks of the TROUBLE LED means that the AD300 on this channel has used cache mode to allow access during a communication loss with the PIB300 or the Access Control Panel. Press the LINK b...:
How close can the top hinge be to the top of the door?
Resolution:
The minimum top and bottom butt hinge locations are as follows: To the hinge centerline: 4 1/2" and 5" hinges = 5 3/8" is the minimum location from top of door to centerline of the first hi...:
Can a door have an InPact device and glass lights?
Resolution:
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...: