What does a blinking TROUBLE LED (D1/D2) mean on the PIB300?

1) Two blinks of the TROUBLE LED means that the AD300 on this channel is not communicating over the RS-485 line. Check wiring connections; verify correct device addressing using HHD/SUS.

2) Three blinks of the TROUBLE LED means that the AD300 on this channel has a Tamper Switch violation. Investigate the lock's Tamper Switch.

3) Five blinks of the TROUBLE LED means that the AD300 on this channel has used cache mode to allow access during a communication loss with the PIB300 or the Access Control Panel.  Press the LINK button for this channel once to acknowledge the trouble and clear the blinking.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.

Other users ask