What is operator voltage

RELATED FAQS

Question
Answer
The Senior Swing operator has a 24VAC output , rated at 1.5 Amps.
If the Main AC fuse is blowing, the control box is defective and needs to be replaced.  The "Main Fuse" is a (5x20MM) 1 Amp Slow Blow fuse. If the 12VAC fuse is blowing, verify they are not trying...
The 4630/4640 Series operator is designed/recommended for a door that will see mostly manual traffic with the occasion automatic/ handicap operation.
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely closed. T...
The 4600 series operator requires a 120 VAC @ 1.5 Amp power input to be field connected. Hardwiring is always recommended, but a "plug-in" line cord can be installed (by others) with the proper cor...
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/9563) have a 12...