Do Von Duprin Exit devices meet the 5 pound force requirement for opening an ADA handicapped door opening?
Resolution:
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device. Maximum allowed force to retract the Von D...:
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
Are the D100 and D200-Series thumbturns ADA compliant?
Resolution:
The D100-Series and D200-Series have ADA compliant thumbturns. See the sell sheet stating ADA compliance.:
Is the B500 and B600, B700, B800 thumbturn ADA compliant?
Resolution:
The Schlage B500-Series and B600/700/800-Series have ADA compliant turns. See our deadbolt literature under downloads.:
Is there an ADA thumbturn offered in the MA locks?
Resolution:
Falcon does not offer an "ADA style thumbturn.:
Does the 8827 with the 248L-4 strike meet ADA?
Resolution:
The 248L-4 strike will not violate ADA. If you change the 248L-4 to the 304L strike, then the latch would need to be lowered.:
Are Ives pulls ADA compliant?
Resolution:
8103EZ and 9103EZ have 2 1/2" clearance the other pulls have 1-1/2" clearance. Check with your local code for clearance required.: