No Door Data Available

RELATED FAQS

Question
Answer
Model 69 the part number is 09-310Model 70 & 73, the part number is WSPART.1075
We have several blank trims listed in the price book to cover existing trim prep in door.  DEVICE EO TRIM   22  230EO  88  880EO   98/99  990EO or 996EO*  33A/35A Rim, 33/3...
Doors are available with cutouts only. This practice is used for field installation of aftermarket (non-Steelcraft) glass trim by either the distributor or end user. The following information must ...
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations. Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
The easiest method to obtain an AL lock for a 2" door is to specify a 2" thick door when ordering.  
Part required by function:2 each A700-043 driver & A700-034** lever insert in addition to the chassis parts below:AL10S – 2 hubs A700-028AL25D – 2 hubs 1 A700-028 (inside), 1 A700-030 (outside)...
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder. 
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. 
CAD drawings are available for doors and frames in 3 drawing formats: Autocad (.dwg) - Release 12 Encapsulated PostScript (.eps) Data Exchange (.dxf) Drawings are available on the...
ALWAYS put the PIM400 in LINK mode first. On a PIM400-TD2 press the LINK1 Button for door one, and LINK2 button for door 2. With a PIM400-485 you must use the SUS/HHD to select which door to LINK.  
1. To put the AD400 in LINK mode, hold down the RTE (Lever or crash bar see below) and press the # key on the key board, or present a card to the reader.            Why press the # key? Because t...
2. AD400 requires a Request To Exit (RTX) signal to link - see the user guide instructions for the linking process.  For an AD400 to enter link mode, it must see the RTX (Request To Exit) switc...
   3. Check the AA battery level, if the AA batteries are below 4.7 volts the AD400 can fail to LINK.             Install fresh batteries, with a level of 6.0 volts or better.  
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are bent a...