minimum size for ND lock
”
RELATED FAQS
Question
Answer
Why can't I remove the control key from the core after the core is inserted into the lever?
Resolution:
The lever may be missing the slot feature for the core locking lug. Verify slot is in place.:
What is the standard backset for the ND locks?
Resolution:
The default backset is 2 3/4" and the latch faceplate dimensions are 1 1/8" x 2 1/4". The latch supplied is the 13-047 deadlatch and 13-048 springlatch.:
How far down can an exit device be cut down in the field?
Resolution:
For most exit devices, please refer to the specific device series catalog for minimum door opening width the device can be cut down to fit. Be aware that some device options, frame...:
What wire gauge is recommended for LCN hardwired actuators?
Resolution:
LCN recommends an 18 AWG (minimum) wire size (gauge) to the 8310 Series hardwired actuators.:
What is the recommended Stile Size for AD and CO?
Resolution:
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.:
How do you order the ND series lock with a small format core?
Resolution:
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core:
How to convert a ND series lock cylinder format from PD to BD?
Resolution:
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...: