maximum door height for concealed closer
”
RELATED FAQS
Question
Answer
Do Steelcraft PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements?
Resolution:
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC 500...:
Do we have a maximum door width or height for using pivots?
Resolution:
The maximum door width that pivots have been tested is a 4' wide door. Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...:
What doors are available with monorail preps?
Resolution:
Monorail cutouts are only available for non fire rated applications.:
What is maximum width, height and weight for IVES butt hinges?
Resolution:
Butt hinges can be used on doors up to 4' wide and 200 pounds. There is no maximum door height. However, an additional hinge must be installed every 30" when exceeding a 7' d...:
What are the maximum door width and height sizes?
Resolution:
Maximum nominal (overall) single door sizes are as follows:L-Series (Laminated Door)20 Gage = 3’ 0” wide X 8’ 0” high18 Gage = 4’ 0” wide X 10’ 0” high16 Gage = 4’ 0” wide X 10’ 0” high1...:
Will the new concealed vertical cable system work with any door height?
Resolution:
:
What is the maximum door weight recommended for LCN closers?
Resolution:
The maximum recommended door weight for LCN closers is 225 lbs.:
Can a 4000T pocket closer go 180 degrees?
Resolution:
The 4000T Series closers have a maximum opening of 90°.:
What is the maximum degree of opening you can template a 4110 Cush closer?
Resolution:
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates. The 4110 if ordered by ST-3220 will allow templating to 135°:
Is there a retrofit closer available for the obsolete 303 OHC closer?
Resolution:
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder. :