lcn door closure

RELATED FAQS

Question
Answer
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit  There is no closer that can replace the old 4030 series closer with the exa...
LCN does not recommend this type of installation, and has never sold a coupler to do this.
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
LCN does not supply Allen wrenches, the size that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting regulation valves: main speed, lat...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8” LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8” STANDARD ROD AND SHOE: ...
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer.  If required, handing can be verified by looking at ...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiring per ST ...