External inhibit function
”
RELATED FAQS
Question
Answer
How do I connect External Inhibit wires on Chexit?
Resolution:
Chexit devices shipped prior to 8-24-2015 were solenoid driven: A normally closed card reader contact, key pad contact or any other control contact connects to the G...:
Does the current Von Duprin ALK have an EI?
Resolution:
Current exit alarm ALK released in November 2010 does ship standard with an EI (external inhibit) option. ALK shipped prior to this would only have EI if ordered as a Special option.:
Is the external inhibit option standard on the " new " ALK from Von Duprin?
Resolution:
The current Von Duprin ALK comes standard with the External Inhibit feature.:
How do I connect the external inhibit option for the Chexit?
Resolution:
For Chexit devices shipped after 8-24-2015 with motor driven connect your normally closed contact from access control system between green and red on the twelve field wire ...:
Why does a Chexit device blink once then powers down?
Resolution:
If Chexit device LED blink once when you turn the unit on, the External inhibit green wire is not by passed or not connected to the access control normally closed contact. For devices sh...:
What is different about the updated Falcon Exit Alarm (EA) option ?
Resolution:
The Falcon Exit Alarm option was updated in June 2012 to include the following benefits. Louder Alarm 95dbs vs 87dbs Easier battery changes 24Vdc hardwire(HW) option included w...:
What would cause the Von Duprin Chexit device to have one red flash when armed then nothing?
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven. The GREEN wire is not shorted to the WHITE if no Access Control system is used.If Access Control system is used,...: