EPT mounting location for door with offset pivots

RELATED FAQS

Question
Answer
EPT can be used on following hinges: Degree of the opening Hinge type Door thickness 0-180 degree Up to 5" butt hinges 1 3/4" 0-180 degree Up to 3/4" offset pivots 1 3/4" 0-130 degree 5 1/2"...
See related solution: Can an EPT be used with Cam Lift Hinges?
The 455 can be mounted on a 48" wide door, but we cannot guarantee that it will withstand the forces involved.  Recommend using 906 instead.
On a single door take the mounting dimensions from centerline of pivots.  On a pair of doors, depending on the door width and pivots being used, the operators can butt up against each other or ov...
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors.  Both units contained within the same Senior Swing header. To order a paired operator with a 2810 on&nb...
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin recommended template locati...
The maximum door width that pivots have been tested is a 4' wide door.  Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...
The minimum door widths for mounting a Senior Swing are: Concealed 2810 Series: 2811 single door (offset pivot or butt hinge) -- 33". 2811 single door with stop (center pivot) -- 36". 2853 pa...
The 2030 Instructions included with the unit has templates for mounting with standard butt hinges, center pivots, and offset pivots.