EL QEL conversion

RELATED FAQS

Question
Answer
HD-EL conversion kit for 3 feet exit device is 050384-00 and for 4 feet is 050385-00.
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...
Yes, the current conversion kits will fit the old style/obsoleted 35 or 35 series vertical rod exit devices. 
Followings are the list of the electric latch retraction EL/HDEL (hex dogging), QEL (quiet) kits: 114317-00 QELA Mod. Conv. Kit 040061-00 QELA Mod. Conv. Kit...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
You need to order the EL98/9947 or 3'  EL conversion kit.  This will fit on 28 1/8" minimum door opening on two vertical x vertical rod device doors.
There is not enough room for both options as the dogging mechanism in a standard cylinder dogging and the electronics for the EL or QEL options are both located at the end of the base plate. For 9...
The 900-2RS is recommended to be used with EL devices but if you have a 900-2Q with PS914 power supply it can be used to operate up to two EL or one EL and one QEL devices .
There is no EL conversion kit for a 2390, the device will need to be replaced.
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
  Pushing on the push  bar or activating the EL/QEL or the trim on Von Duprin XP98/99 exit device does not retract the latch, it releases the latch only. Door must be pushed or pulled when device o...
You cannot convert the old Von Duprin 33/35 rim exit device to EL electric latch retraction as the device center case was different than EL33/35 rim center case assembly.
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.
The old MPB842 power supply will power up to two EL electric panic bars but will not power the QEL devices.  A defective potted module inside the electric panic bar or defective power supply coul...
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
Yes, part numbers for Falcon electric latch retraction EL conversion kits are as follows: 650147 for a 3' device. 650148 for a 4' device. 
The EL wiring adapter is not needed for QEL devices.
There is no conversion kit to add EL or ED to an existing 1690 or 1790 series device. All of the components are built into the device, since the device does not have a separate baseplate.  You ...
The Von Duprin PS914-2RS retracts the EL or QEL device approximately 200 times with five second hold time after each pull.
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. 
Yes, the QEL device includes a cable assembly part number 110388-00.Since 12/2014, that cable comes in a package (part 116549) with the long cable mentioned above and the small cable that plug...
The Von Duprin EL33A/35A/98/99 devices can be converted to the QEL devices by getting correct sized QEL conversion kit and a 900-2Q option board for the PS914 power supply. 3' Conversion Kit #05...
Kits are available per the following criteria.    Product Bulletin Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish  Optional LX...
An EL device can't be converted to mechanical device. If the device is not connected to the power supply, it would function mechanically but no mechanical dogging option.