How do I specify temporary construction cores?
Resolution:
Use the cylinder suffix 'T' for full size interchangeable core or the cylinder suffix 'HD' for small format interchangeable core, see Figure 1. Small format also has a disposable core option ...:
What does the cylinder suffix BDC mean?
Resolution:
A small format disposable core is used as a SFIC construction core that is for low security applications and can be thrown in the waste bin after use.:
How to order the mortise full size interchangeable core with a construction core.
Resolution:
This only applies to the full size interchangeable cores. The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed). Simply add (-ICX) to the end o...:
Is the B250 series deadbolt available with a small format interchangeable core?
Resolution:
The B250 product line is not available in the SFIC platform.:
How to order a T series lock with a Corbin Russwin full size interchangeable prep.
Resolution:
Specify the J cylinder suffix followed by IC-CR6 or IC-CR7 (6 or 7 pin Corbin core) Example: T581J IC-CR6 This will accommodate an 8000 or 8000-7 Corbin Russwin Full Size core.:
What is the part number for T lock tailpiece used with a conventional cylinder?
Resolution:
Refer to Table 1 for a list of T lock tailpieces for conventional cylinders. Table 2 shows IC tailpieces. Table 1: T lock conventional tailpieces Table 2: T lock IC tailpieces:
Can I get the RU series with a Schlage Full Size Interchangeable core?
Resolution:
The RU lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied. The tailpiece will come with the lock. Example: RU581J IC-SC:
Can I get the T series with a Schlage Full Size Interchangeable core?
Resolution:
The T lock can accept a Schlage Full Size core, but the cylinder suffix must be specified as "J IC-SC" so the correct parts are supplied (including the tailpiece) Example: T581J IC-SC:
How do you order the ND series lock with a small format core?
Resolution:
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD GD = Schlage SFIC core HD = Construction core BD = Less core BDC = Plastic temporary construction core:
What are the thermal factors for Steelcraft door products?
Resolution:
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners) U-Factor = 0.50 R-Value = 2.01B16 Series (Steel Sti...:
What cores are offered for insulated doors?
Resolution:
Insulated Core Options: Steelcraft L-Series doors are available with the following 2 optional insulated cores: Polystyrene slab - this core is available in non fire rated and fire rated doors...:
What is the maximum glass size available on the T-Series door?
Resolution:
Glass lights are available in fire rated T-Series doors: Limited to one (1) light per door leaf with a maximum of 100 square inches of exposed glass. This applies to all hourly ratings a...:
What versions of Microsoft Windows are compatible with Schlage Express version 4.4.2?
Resolution:
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...:
Can you use a Senior Swing controller as a replacement for an obsolete Mid Swing controller?
Resolution:
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...:
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
Can an ND lock with SFIC cores be extended to fit a 3" extended outside door?
Resolution:
ND locks can be extended up to 6" Extended Outside. :