Resolution

Yes. Remove the receiver from the operator. Remove the transmitter from the actuator button. Attach 1 wire to the NO (normally open) contact on the actuator switch, and another wire to the COM (common) contact on the actuator switch. Connect these 2 wires up to the activation terminals of the operator.