Solution ID
Resolution
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device must have a separate Power Supply for motorized electric latch retraction, such as the Von Duprin 900 series power supply.
Wiring for "Fail Secure" strike:
- Connect (-) lead of strike to terminal 2.
- Connect (+) lead of strike to terminal 23.
- Connect a (Jumper) wire from terminal 3 to 22 (for 24VDC), or from 5 to 22 (for 12VDC) strike.
Wiring for "Fail Safe" strike or maglock:
- Connect (-) lead of strike to terminal 2.
- Connect (+) lead of strike to terminal 24.
- Connect a (Jumper) wire from terminal 3 to 22 (for 24VDC), or from 5 to 22 (for 12VDC) strike.
Wiring for "Fail Secure" EL device (Von Duprin):
- Connect terminal 22 to the "SC" terminal of the Von Duprin 900 Series power supply.
- Connect terminal 23 to the "I1" terminal of the Von Duprin 900 Series power supply.
- Connect the EL device to the "O1" and "GND" terminals of the Von Duprin PS914-2RS Series power supply.
Notes
Wiring diagrams for a 12VDC or 24VDC Strike/Maglock and an EL device are shown on page 14 of installation booklet.
4630/4640 Installation Instructions
For additional common diagrams or further info, please contact Allegion Product Support by email at closers_techprodsupport@allegion.com or call 877-671-7011 option 2, option 4.