Solution ID
Resolution
Battery Jump Procedure: The emergency battery jump start can be used to unlock the door if the batteries are dead. WARNING: The lock will remain unlocked until you change the battery and relock the door.
1. Touch a new high-quality alkaline 9-volt battery to the contacts below the bolt throw.(There is no specific way the battery has to touch the connection points).
2. Wait for 1 red light and then 3 green lights with 3 beeps. (The lights are below the Schlage logo).
3. Present a valid credential.
4. Rotate the bolt throw away from the door edge.
5. Replace the batteries.
6. Present a valid credential and relock the lock to ensure proper lock operation. (The lock will remain unlocked until you change the battery and relock the door).
Thank you for your feedback. Please tell us why this solution did not meet your needs.
If you would like a reply to your comment, click HERE to submit your comment or inquiry.