Question
Answer
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
What special template (ST) is used with a 2030 closer and GJ over head stop?
Resolution:
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...:
Where is the template for the 718 trims made after 2/28/2011 for Falcon/Monarch concealed vertical rod devices?
Resolution:
Templates for current 718 series trim can also be found on Falcon website:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
Resolution:
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiri...:
Can a 24-R, 24-V, 25-R, or 25-V device use just a cylinder on the pull side for NL-OP function?
Resolution:
This is possible. A rim cylinder with cylinder anchor plate is used (anchor plate provided with rim cylinder package). No other special components are required. Order device as NL-OP.&...:
What is the SUS feature "Device Template"
Resolution:
See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution: