xp latch force

RELATED FAQS

Question
Answer
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. 
120V Models: The hold open force on the 2310ME / 4310ME / 4410ME closers is "NOT" adjustable. 24V Models: There is a trimpot adjustment on the circuit board that allows you to "REDUCE" the hold op...
The SEM series magnets have a holding force of approximately 35 lbs when installed according to LCN instructions.
The manual opening force to required to open a Sr Swing operator is approximately 11-12 lbs.
The size 6 handed closers will have the most (strongest) closing force. The 4016 (pull side), the 4026 (top jamb push side) or the 4116  (push side parallel arm)  have the highest closing force.
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual  opening force, and reduced force "RF" required 11 lbs of manual opening force.  All S...
The manual opening force on a 4630/4640 will be approximately 8.5 lbs to 14 lbs depending on the spring setting.
Cylindrical Locks: a bored lockset whose latch or bolt locking mechanism is contained in the portion installed through the cross-bore Medium, high to extra heavy duty Commercial, mul...
Locknetics company supplied electro-magnetic locking devices, electronic smart locks, and electronic security components to access control dealers and lock smiths.  Ingersoll-Rand acquired ...
  The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulati...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...
Yes, the spring torque on 3SP1 butt hinge is adjustable.  See instructions at this link:https://static-or01.inbenta.com/fc7332911aa38d5387ffdef79e8605c6ecdc727ece31acf5bc8e26dcac5d29e4/Iv...
-         With the CIP NOT inserted and the Schlage Utility Software (SUS) running o   Enter the Master Programming PIN or Present Loc...
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual pr...
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the XP...
UL437 is testing requirement that cylinders pass both a timed cylinder pick test and a forceful core/cylinder pull test.  We have various cylinders to meet this need, please reference our price boo...
The EL (Electrified) option is available with Von Duprin XP98/99 exit devices. To order, specify ELXP98/99 with proper trim.
Force, Spring, Spring Size, Closer Size
Extra Protection
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.
Installation is not correct. If the straight cam on the mortise cylinder is not inverted,  the latch may be forced out of the strike and cause the door to unlatch.  Please reference the ...
The Schlage Vandlgard option available on select L-Series, LV-Series, and ND-Series and is ideal for areas subject to abuse or anywhere vandalism is likely to be present, such as schools, univ...
Vandlgard is specified by "LV" for mortise locks. The L9000 is a mortise style lock that mounts into a pocket mortised into the edge of the door.Vandlgard is specified by ND9x functions f...
Refer to table 1 for the list of Schlage AL-Series cylinders.     AL-Series Cylinder Reference Table    Function  Cylinder Mechanism   Complete Cylinder   Non-Hotel Functions  ...
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device.  Maximum allowed force to retract the Von D...
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before coming completely ...
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device.  Be sure this screw is installed- Exit hardware and strike must be properly mounted ...
Von Duprin does not recommend using XP98/99 devices with any electric strike.   Von Duprin recommends using the standard 98/99 rim device.  The XP device has 2000 pound holding forc...
This application is not recommended as elelctric strikes have never been tested with XP98/99 exit device because it would defeat the XP device holding force purpose.   The holding force f...
When Privacy Mode is entered, the lock is secured as part of the Privacy Mode process.
When Privacy Mode is cancelled, if the lock is still within the Auto-Unlock period, the lock toggles unsecured.
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.
This can only be done if you have an Encode, and have it paired through Schlage Home. To do this, you will have to check the RSSI: How to check RSSI: •    Open Schlage App • &nb...
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
Warranty Statement   3 Year Limited Mechanical Warranty and 1-Year Limited Electromechanical Warranty - Additional warranties listed below The provisions of these limited warr...
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...
Standard Schlage cylinders will not fit in Yale locks, but Schlage does offer special retrofit cylinder that, when ordered, can fit into specific Yale locks.  See below for retrofit options.  ...
Verify the door thickness is 1 5/8" or greater per the pricebook.  Thin doors will force the clip off the housing.  If door thickness is correct then replace the product as needed. ...
Primus XP was released on 11/08/2007 with the following highlights: The XP is patented until 2024. Primus XP has the addition of a new #7 fingerpin with a unique angle combined with a new pocke...
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
Calibration is an internal process of the QEL device when energized the 1st time.  The solenoid will pull and drop 3 times on a standard calibration.  Calibration can be forced by pr...
ADA, ada Code, Spring Tension, Spring