Question
Answer
Can you manually pull a 4040SE out of hold open?
Resolution:
The holding force on an SE/ME Series door closer is approximately 35 lbs. and they can be manually pulled out of hold open with approximately 35 lbs of force. :
What is the holding force of a SEM magnet?
Resolution:
The SEM series magnets have a holding force of approximately 35 lbs when installed according to LCN instructions.:
What LCN closer has the strongest closing force?
Resolution:
The size 6 handed closers will have the most (strongest) closing force. The 4016 (pull side), the 4026 (top jamb push side) or the 4116 (push side parallel arm) have the highest closing force.:
Can I get a Senior Swing with a reduced opening force gearbox?
Resolution:
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual opening force, and reduced force "RF" required 11 lbs of manual opening force. All S...:
What is the amount of pre-load force allowed for the 6300 electric strike before the strike will no longer release and operate properly.
Resolution:
The 6000 series electric strikes 6100, 6200, 6300 models, require that there be no preload at all on the strike lip to function properly.:
What is the opening force of a 4600 Series (4630/4640) operator when used manually?
Resolution:
The manual opening force on a 4630/4640 will be approximately 8.5 lbs to 14 lbs depending on the spring setting.:
What is a cylindrical lock?
Resolution:
Cylindrical Locks: a bored lockset whose latch or bolt locking mechanism is contained in the portion installed through the cross-boreMedium, high to extra heavy dutyCommercial, multi-family and ins...:
Is there adjustment limits on the regulation valves of LCN manual closers?
Resolution:
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valv...:
What is the difference between Panic Hardware and Fire Exit Hardware?
Resolution:
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device. There are some internal parts that may be different and the method it is secured to the d...:
What is a Senior Swing 9540 RF?
Resolution:
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...:
Is the spring torque on 3SP1 hinge adjustable?
Resolution:
Yes, the spring torque on 3SP1 butt hinge is adjustable. See the 3SP1 instructions: :
How do I program Locknetics CM / CL legacy locks with the Schlage Utility Software (SUS) and Hand Held Device (HHD)?
Resolution:
- With the CIP NOT inserted and the Schlage Utility Software (SUS) running o Enter the Master Programming PIN or Present Loc...:
CM Lock Manual Programming Disabled
Resolution:
When trying to program a CM lock, it may display an error code with a solid green light and 10 read flashes. This indicates the lock has already been programmed with computer software and manual ...:
What cylinders are available with UL437?
Resolution:
UL437 is testing requirement that cylinders pass both a timed cylinder pick test, a forceful core/cylinder pull test as well as a destructive entry test. We have various c...:
Is the Von Duprin EL option available on Von Duprin XP98 or XP99 exit devices?
Resolution:
The EL (Electrified) option is available with Von Duprin XP98/99 exit devices. To order, specify ELXP98/99 with proper trim.:
CLOSING FORCE
Resolution:
Force, Spring, Spring Size, Closer Size:
XP
Resolution:
Extra Protection:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
How does the latch bolt retract on the Von Duprin XP device?
Resolution:
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.:
Why would the 25-R latch release the door by applying repetitive force to the 510L lever handle?
Resolution:
Installation is not correct. If the straight cam on the mortise cylinder is not inverted, the latch may be forced out of the strike and cause the door to unlatch. Please reference the ...:
What is the part number for an AL Series cylinder?
Resolution:
Refer to table 1 for the list of Schlage AL-Series cylinders. AL-Series Cylinder Reference Table Function Cylinder Mechanism Complete Cylinder Non-Hotel Functions ...:
Do Von Duprin Exit devices meet the 5 pound force requirement for opening an ADA handicapped door opening?
Resolution:
The 5 pound force requirement is in reference to the maximum force to swing the door, not the maximum force allowed to unlatch the exit device. Maximum allowed force to retract the Von D...:
What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
Why doesn't full rotation of the AD or CO Series Exit Trim (993) outside lever fully retract the Von Duprin 98/99 Exit Device latch?
Resolution:
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device. Be sure this screw is installed- Exit hardware and strike must be properly mounted ...:
What electric strike can be used with the XP98/99 devices?
Resolution:
Von Duprin does not recommend using Electric Strikes with XP98/99 Rim Exit Devices.The design of the latchbolt creates a stronger holding force when used with the 909 or 954 mechanical strikes desi...:
How does Privacy Mode work with Auto-Unlocks?
Resolution:
If the lock is NOT within an Auto-Unlock period when Privacy Mode is cancelled, the lock stays secured.:
How to test wifi signal strength to lock?
Resolution:
This can only be done if you have an Encode, and have it paired through Schlage Home. To do this, you will have to check the RSSI: How to check RSSI: • Open Schlage App • &nb...:
What versions of Microsoft Windows are compatible with Schlage Express version 4.4.2?
Resolution:
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...:
Does Falcon have a breakaway lever trim feature on mortise locks?
Resolution:
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
What is the cylinder part number for an ND-Series lock?
Resolution:
ND-Series Cylinder Reference Table Function Door Thickness Cylinder Mechanism Complete Cylinder Non-Hotel Functions Standard Conventional 23-065 Primus 20-765 Pri...:
Do we have a Schlage conventional retrofit cylinder for Yale locks?
Resolution:
Standard Schlage cylinders will not fit in Yale locks, but Schlage does offer special retrofit cylinder that, when ordered, can fit into specific Yale locks. See below for retrofit options. ...:
Clip on the B500 or D200 SFIC deadbolt comes off shortly after installation.
Resolution:
Verify the door thickness is 1 5/8" or greater per the pricebook. Thin doors will force the clip off the housing. If door thickness is correct then replace the product as needed. ...:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...:
Which strike do you use with an XP98/99 device?
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.:
How is the QEL calibrated?
Resolution:
The QELA motor that has shipped since 2015 is self calibrating. Older versions had a calibration button, and these notes would apply: Calibration is an internal process of the QEL device&...:
OPENING FORCE
Resolution:
ADA, ada Code, Spring Tension, Spring: