Question
Answer
What electric strike can be used with the XP98/99 devices?
Resolution:
Von Duprin does not recommend using Electric Strikes with XP98/99 Rim Exit Devices.The design of the latchbolt creates a stronger holding force when used with the 909 or 954 mechanical strikes desi...:
Which strike do you use with an XP98/99 device?
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.:
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...:
How does the latch bolt retract on the Von Duprin XP device?
Resolution:
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...:
Is there an electric strike that will work with the 2670 Guard X?
Resolution: