wiring diagram benchmark ada operator
”
RELATED FAQS
Question
Answer
Will the 9100 series Benchmark III power an electric strike?
Resolution:
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...:
What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
How do you install the arms on a 9100 Series Benchmark operator?
Resolution:
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...:
What are ElectroMechanical Automatic Operators?
Resolution:
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...:
What is maximum reveal for the 9140?
Resolution:
Reveal should not exceed: 6" for the REGULAR ARM 9 3/4" for the LONG ARM:
How do you change a 9130 Benchmark to a 9140 Benchmark?
Resolution:
The only difference between the 9130 and 9140 Benchmark operators are the arms.To convert a Benchmark 9130 (pull) to a 9140 (push), order a 9140-3077 push arm assembly for revea...:
How do I fix a Benchmark 9100 that the belt keeps sliding down on motor gearbox?
Resolution:
The Benchmark and Falcon operator gearbox assemblies are not repairable. The gearbox belt and/or pulley cannot be replaced in the field, the gearbox would need to be replaced as a complete assembly...:
Can a 9100 series Benchmark be used on a high traffic exterior door?
Resolution:
The recommended application for the 9100 series Benchmark operator is low traffic exterior doors, or low/moderate traffic interior doors. The Benchmark series operator "is not" recommended for use ...: