will an ND latch work in D series
”
RELATED FAQS
Question
Answer
What is the standard backset for the ND locks?
Resolution:
The default backset is 2 3/4" and the latch faceplate dimensions are 1 1/8" x 2 1/4". The latch supplied is the 13-047 deadlatch and 13-048 springlatch.:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
Can the 8200 Series operator power a electric strike?
Resolution:
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.:
Will the Von Duprin 376T control accept a 1 1/8" mortise cylinder?
Resolution:
The Von Duprin 370 series control required a 1 1/4" mortise cylinder and will not operate with 1 1/8" mortise cylinder.:
Are the batteries for the PS 914 BBK the same as the ones from the 873 BB?
Resolution:
The battery for the PS873 and PS914 are the same, 7AH sealed Lead Acid battery.:
What is the difference between the standard lever inserts for the pre-2002 AL and the old D Lever?
Resolution:
The old D-Series Lever used a standard lever insert similar to the pre-2002 AL-Series standard lever insert. The old D Lever insert was smaller than the AL and the two were not comp...: