Why will my ALK kit not go into alarm
”
RELATED FAQS
Question
Answer
If using the alarm kit-ALK with the 99 device what power supply is needed?
Resolution:
Exit alarm ALK operates with 9VDC battery and doesn't required a power supply.If you choose to hard wire the exit alarm ALK use the PS902 power supply.Exit alarm ALK requires 24VDC regulated power ...:
What is the current draw of a Von Duprin exit alarm kit ALK?
Resolution:
The current draw of a Von Duprin exit alarm ALK is .25 amp when alarm is activated.:
Can the Von Duprin ALK alarm kit be operated with 12 volts DC?
Resolution:
No, the Von Duprin ALK alarm kit can only be operated with a 9 volt battery or 24 volts DC hard-wired power. :
Why is the Von Duprin exit alarm ALK going into alarm on it's own?
Resolution:
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...:
The Von Duprin 98 or 99 ALK kit will not sound the horn
Resolution:
Followings are the reason for 98/99 exit alarm ALK not sound when push bar is activated. Make sure key switch on exit alarm ALK is turned on, wait for 20 seconds before you activating the pushba...: