Which mullions are approved for HH devices
”
RELATED FAQS
Question
Answer
What mullions should be used with XP devices?
Resolution:
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...:
How far can a 4ft EL 99R device be cut down to?
Resolution:
EL98/99-4 ft rim device required minimum of 35.2" with 5/8" stop height door opening on single door and 35.56" with 4954/9954 mullion.:
What is the backset for a 98/99 rim device with a 1609 strike?
Resolution:
The backset for a 98/99 rim PANIC device with 1609 strike is 2 3/8" from center of the opening to center line of the device. See template :
What strike would be used for a 25-R for pair without mullion?
Resolution:
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.:
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
Exit Device Backsets
Resolution:
Backset dimensions will vary depending on the device, application and the opening configuration. If you have questions on specific device backsets, please e-mail your request (including a descripti...: