Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
Which electric lock can be used with an exit device?
”
RELATED FAQS
Question
Answer
Can the 5100 electric strike be used with a mortise exit device?
Resolution:
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
Does Falcon offer a Delayed Egress exit device?
Resolution:
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-24 or RX-25 Series can perform a delayed egress by using the DE5300 controller, power supp...:
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
Why is the electric E996L-FSE trim used with a Chexit CX99 exit device?
Resolution:
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...: