WHICH COORDINATOR BE USED ON EXTERIOR DOORS

RELATED FAQS

Question
Answer
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
No, the geometry of a swing clear hinge prevents the coordinator from working correctly.  The bar style coordinator will not hold the active door open far enough for the inactive door to clear the ...
The 571 strike is used on the in-active door leaf of a pair or on the 19-V door leaf when both doors are active per template.
There are 2 types of door coordinators available: Bar Coordinators (Ives COR Series): Surface mounted to the bottom surface of the frame soffit. The active door lever, located nearest to th...
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
The recommended application for the 9100 series Benchmark operator is low traffic exterior doors, or low/moderate traffic interior doors. The Benchmark series operator "is not" recommended for use ...
For non fire rated doors only the 1609 strike would be used on the inactive leaf that is flush/surface bolted or with a *surface or concealed vertical rod device on other door leaf.