Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
Can you use the 925 tubing from LCN for the PN Von Duprin devices?
Resolution:
If using the LCN pneumatic control box as the air source for the Von Duprin Pneumatic devises then you have to use the LCN 925 tubing because of the size of air line fitting on the LCN co...:
Does Von Duprin have an exit device that is pneumatic?
Resolution:
The Von Duprin Pneumatic or "PN" device does not have a specific listing or certification pertaining to hazardous locations.:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...:
Which of the Pneumatic operators uses the same cylinder?
Resolution:
The 4840 and the 4810 are they only cylinders that can be interchanged, they use the same cylinder for their individual applications.:
Does any of the Ives VR trims work with non-IR exit devices?
Resolution:
You will need to check with the other manufacturer. Check the template for the other manufacturer to see if the hole pattern for the trim and the cylinder location would match up. The VR trim cou...:
Can the Falcon Monarch 718C or 718NL trim be used with the 25-C exit device?
Resolution:
The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device. The 718C trim is listed in the Price Book for the 25 series The instructions attache...:
What cylinder is used in a 210K trim for the 22 series exit device?
Resolution:
Equivalent to the Schlage D series line with a C keyway. Part number 21-002.:
Which strike do you use with an XP98/99 device?
Resolution:
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...:
Can the 5100 electric strike be used with a mortise exit device?
Resolution:
The 5100 electric strikes are for use with cylindrical locks only. Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
Do we have instructions on how to clean an exit device?
Resolution:
Recommendation is to use mild soap with a damp cloth to clean an exit device.:
Does Von Duprin offer an exit device for exterior use?
Resolution:
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...:
Does Falcon offer a Delayed Egress exit device?
Resolution:
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-24 or RX-25 Series can perform a delayed egress by using the DE5300 controller, power supp...:
What finishes should be used on exit devices near the ocean or in saltwater environments?
Resolution:
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...:
Can the EL or QEL conversion kit be used on the old Von Duprin 33/35 exit device?
Resolution:
Current EL and QEL baseplate conversion kits can be used on all latching types of the 33/35 series (non "A" version which were manufactured prior to 2003). At one time, the obsolete black EL ...: