what size cylinder can i use with von duprin exit devices?

RELATED FAQS

Question
Answer
Standard exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK option on non fire rat...
 A 1 1/4" cylinder with straight cam is required for the Von Duprin SD (Special Dogging) exit device option.
The cylinder cam must be inverted with the SD option to work properly.
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
The ALK uses a 1 1/4" mortise cylinder with straight cam. (NO DOGGING)
The rim cylinder with thumbturn, XB11-979 (Figure 1) was designed to be installed on the inside head of the Von Duprin 98/99–2 double cylinder exit devices, see Figure 1. The rim cylinder with...
A 1 1/4" mortise with straight cam similar to the Schlage B502-191 is needed when using Von Duprin 9975 mortise device with 996L-M trim.
 The tailpiece of the rim cylinder can be inserted into the Von Duprin 98/99 rim device either vertical or horizontal.
Double cylinders are only available on Von Duprin 98/99 Rim and 98/9975 Mortise devices.
A 3' exit device can not be modified to a 4' exit device. You will need to replace the device with a 4' one.
A double cylinder(-2) option is not available on a Falcon device but is available from Von Duprin.
Equivalent to the Schlage D series line with a C keyway. Part number 21-002.
You must use the drive bushing that is supplied with the 179L control trim.  It is different from teh 1790 bushing.
Step 3 and 4 of 179L Instructions will show the old drive bushing being removed & the new drive bushing getting installed
The 09-611 indicator stands off the door 0.39".
The pricebook suggests (for a 1-3/4" door) using a 1-3/8" cylinder when installing with an 09-611 occupancy indicator.
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2. Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an outside...
The 98/99 rim device can be converted to double cylinder 98-2 or 99-2. Double cylinder features an inside key cylinder which locks or unlocks the outside trim (Classroom Function) and an outside c...
The Von Duprin PS914 power supply must be used on the EL devices with either the 900-2RS or 900-4RL option board since the EL devices requires power supplies set at 24VDC to be able to provide the ...
  You can use a Von Duprin PS914 power supply with any of the following option boards depending on the application. 900-2RS board  will power 1 or 2 devices that do not require timing from pow...
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.
Part numbers for Schlage and Falcon cylinders for Von Duprin devices are listed below. (KIL = Key In Lock) SCHLAGE   Mortise Rim KIL ...
FALCON   Mortise Rim KIL Conventional 986 x #4 cam 951 A23165-02 Small Format Housing C987...
If unclear whether mortise, rim, or key-in-lever is needed, reference links below to determine what cylinder type is needed.  In order to determine cylinder type needed,  you must first k...
All Von Duprin 370 Series trims require a 1 1/4" mortise cylinder with a straight cam.
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
Panic devices are not designed for exterior application. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish and may void&n...
Water and electricity do not mix.  Von Duprin electrified devices can NOT be used in an exterior environment.
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
The Von Duprin 98/99EO exit devices will accept any of the exterior trims that we offer for 98/99 exit devices without any extra parts. 996L, 996L-NL, 996L-DT, 996L-BE, 990NL, 990DT, and 110NL a...
A 1 1/4" mortise cylinder with straight cam (similar to the Schlage B502-191) or a 1 1/2" mortise cylinder with straight cam using supplied spacer collar. Cylinder length does not chan...
Chexit devices shipped after 8-24-2015 with motor driven: The Chexit device will use a 1 1/4" mortise cylinder with straight cam. Schlage cylinder 20-001-114 recommended. CAUTION: The length of t...
Chexit devices shipped prior to 8-24-2015:The CX device will need a 1 1/4" mortise cylinder with a straight cam per page 2 of the installation instructions. A 996L-M for a 1 3/4...
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...