what lock functions can be supplied with DM deadbolt monitor?
”
RELATED FAQS
Question
Answer
L9493EL/EU
Resolution:
Electrically locking and unlocking both levers (outside cylinder, inside thumbturn with deadbolt) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (pow...:
L9492EL/EU
Resolution:
Electrically locking and unlocking outside lever (outside cylinder, inside thumbturn with deadbolt) - Outside knob/lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (...:
L9494EL/EU
Resolution:
Electrically locking and unlocking outside lever (inside and outside cylinder with deadbolt) - Outside lever continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power failur...:
L9495EL/EU
Resolution:
Electrically locking and unlocking both levers (inside and outside cylinder with deadbolt) - Both knobs/levers continuously locked (EL) or unlocked (EU) by 12 or 24V DC. EL is fail safe (power fail...:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
Is the MA lock available with the RX feature?
Resolution:
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever. The switch is only available as Normally Open (NO).:
Why does the Schlage Utility Software application display the error message "E201 - This device is not connected?"
Resolution: