What size wire and run is recommended when using a PS914-2RS?
Resolution:
For Product Shipped Prior to August 2012 using the old (black) potted module:a. 0-100 ft 14 gauge wireb. 0-200 ft 12 gauge wire&nbs...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...:
What is the default password to log into HandNet for Windows?
Resolution:
Log in is "1234" and the password is "new".:
What are the differences between the old PCB and the new PWM?
Resolution:
The new potted module ( PWM ) operates with a soft start, gradually increasing the input on time to the pull coil until it is on 100% of the time. This results in less noise when EL solenoid is pul...:
What is the part number for the SFIC tail piece for a W lock?
Resolution:
Q330-168 SFIC Tailpiece (throw member for levers) Q330-169 SFIC Tailpiece (throw member for knobs) :
What is the maximum door thickness a Rim cylinder can fit on?
Resolution:
For total thickness measurements larger than 3 inches see the special cylinder offerings in the Schlage Pricebook. Specify the part number and include the total thickness. We do no...:
What is the part number for the Von Duprin 15 second CX sign?
Resolution:
113781 is the part number for Von Duprin 15 second CX sign.:
Can a 4640 operator be mounted on a Flush Ceiling application?
Resolution:
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.:
What is the part # for the 4954 mullion bottom fitting?
Resolution:
The part number for a Von Duprin 4954 mullion bottom fitting is #050390.:
Will Falcon B locks prepped for BD accept a 6 or 7 pin core?
Resolution:
The B series accepts 6 or 7 pin small format cores when specifying with the "BD" cylinder suffix (less small format interchangeable core). The tailpiece shown below is used for bo...:
Why would a Falcon 8200 Series operator be blowing the fuse?
Resolution:
If the Main AC fuse is blowing, the control box is defective and needs to be replaced. The "Main Fuse" is a (5x20MM) 1 Amp Slow Blow fuse. If the 12VAC fuse is blowing, verify they are not trying...:
What do I need to do to make my 4041 Reg/PA a hold open arm?
Resolution:
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...:
What is the difference between Von Duprin EL and E functions?
Resolution:
Application is based on how the door will be used. Please contact Product Support at 877-671-7011 to discuss your application and select the correct device for your opening.: