Why is the Von Duprin exit alarm ALK going into alarm on it's own?
Resolution:
The following may cause the ALK to go into alarm: Make sure red and blue wires on the RX switch are connected to the exit alarm ALK terminal block and yellow wire is taped off. Check the red an...:
Are the Pushbar Retrofit Kits (PBKIT) the same for 98/99 and 33A/35A series devices?
Resolution:
A PBKIT is a Pushbar Retrofit Kit.The pushbar retrofit kits are not the same for 33A/35A and 98/99 series exit devices. Depending on the finish of the exit device, the pushbar end caps are di...:
What is the minimum top rail required on a door for 1461 Rw/PA?
Resolution:
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate. If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.:
Does the push bar end cap come as a separate item or do you have to order the push bar kit on the 33/35A or 98/99?
Resolution:
How to order: specify devise type, size, and finish. Example: PBKIT 33A 3' US28: